Knowledge Library · 10 topics

Corrosion and Coatings

From Tafel and polarisation resistance (Rp) to VASP/CASP, from electrochemical noise to pitting and concrete corrosion; the effect of ohmic drop on corrosion-current determination.

Corrosion –  Application Note 10

How is the corrosion current measured with the Tafel and LPR (Rp) methods?

Corrosion-current determination on an iron electrode in acid solution by Tafel extrapolation and polarisation resistance (Stern-Geary); EC-Lab® Tafel Fit and Rp Fit tools.

Sections of the note: Introduction · Experimental Conditions · Protocol Description · Stern Method (Tafel Fit) · Stern and Geary Method (Rp Fit) · Conclusion

Download PDF Source: biologic.net · Updated: August 1, 2024
Corrosion – Application Note 22VMP3 → VMP-3e

How is rebar corrosion in reinforced concrete monitored electrochemically?

Rp and EIS measurement on steel in concrete, ohmic-drop correction due to the high resistance and long-term monitoring with the VMP3 (today VMP-3e).

Sections of the note: Introduction · Experimental Conditions · Results · Calculation of Polarization Resistance · Realkalization · CHARACTERIZATIONS OF THE METALLIC ROD.

Current model: The VMP3 has been discontinued; its current counterpart is the 16-channel VMP-3e.
Related products:VMP-3eSP-200
Download PDF Source: biologic.net · Updated: September 25, 2026
Corrosion –  Application Note 25SP-150 → SP-150eSP-50 → SP-50eVMP3 → VMP-3eVSP → VSP

How is pitting corrosion evaluated on multiple samples?

Pitting and repassivation potentials by cyclic polarisation; parallel sample testing with a multichannel instrument (VMP3/VSP → VMP-3e/VSP-3e).

Sections of the note: Introduction · Experimental Conditions · Results · LP Investigations · MPP Investigations and Statistics · Conclusion

Current model: The SP-150 has been replaced by the SP-150e.
Current model: The SP-50 has been replaced by the SP-50e.
Current model: The VMP3 has been discontinued; its current counterpart is the 16-channel VMP-3e.
Current model: The VSP is still available in the Essential range; for energy applications the VSP-3e is recommended.
Download PDF Source: biologic.net · Updated: January 31, 2024
Corrosion – Application Note 36SP-300

How are Rp and the Tafel coefficients determined with the VASP technique?

Rp, βa and βc in a single measurement with variable-amplitude sinusoidal polarisation (VASP); application with the SP-300 and comparison with classical methods.

Sections of the note: Introduction · Experimental setup · Results · Conclusion

Related products:SP-300EC-Lab®
Download PDF Source: biologic.net · Updated: July 17, 2024
Corrosion AN37

How is Rp determined with the CASP technique?

Calculation of corrosion parameters from the harmonics of constant-amplitude sinusoidal polarisation (CASP). (The source file was downloaded incorrectly; the summary will be completed when it is re-supplied.)

Related products:SP-300EC-Lab®
Corrosion –  Application Note 39-1SP-200SP-240 → SP-300SP-300VMP-300VSP-300

Electrochemical noise measurement 1: How is instrument noise validated according to ASTM?

Measurement of the instrument noise floor with a dummy cell under ASTM G199; noise performance of the SP-200/SP-300/VSP-300 and the ULC option.

Sections of the note: Introduction · ASTM Requirements · Experimental Setup · Results · Conclusion · Appendix

Current model: The SP-240 has been discontinued; its current counterpart is the SP-300.
Related products:SP-300VSP-300SP-200
Download PDF Source: biologic.net · Updated: January 31, 2024
Corrosion –  Application Note 39-2VSP-300

Electrochemical noise measurement 2: ASTM evaluation on a real system

Noise recording in ZRA mode in a real corrosion cell, data processing and ASTM evaluation of results obtained with the VSP-300.

Sections of the note: Introduction · ASTM Experiment · ASTM Comparison · Conclusion · Appendix

Related products:VSP-300
Download PDF Source: biologic.net · Updated: January 31, 2024
Corrosion –  Application Note 39-3SP-200SP-240 → SP-300SP-300VSP-300

Electrochemical noise measurement 3: How is the noise resistance Rn calculated?

Rn determination from the standard deviations of potential and current noise, its relationship with Rp and use of the EC-Lab® ENA tool.

Sections of the note: Introduction · Experimental Conditions · Impedance Measurement · Noise Measurements · Results · Impedance Measurement

Current model: The SP-240 has been discontinued; its current counterpart is the SP-300.
Related products:SP-300VSP-300
Download PDF Source: biologic.net · Updated: January 31, 2024
Corrosion – Application Note 47

How is the corrosion current determined under mass-transfer-limited corrosion?

In oxygen-reduction-limited systems the Stern relation does not hold; the note gives the appropriate fit model in EC-Lab® and the interpretation of the results.

Sections of the note: Introduction · Corrosion with mass transfer limitation · I vs. E Relationship · Dummy cell · Stern method (Tafel fit) · Stern and Geary method

Related products:EC-Lab®SP-200
Download PDF Source: biologic.net · Updated: June 5, 2026
Corrosion –  Application Note 48

How much does ohmic drop mislead corrosion-current determination?

How uncorrected IR drop distorts Tafel slopes and Icorr; the effect of correction with ZIR with numerical examples.

Sections of the note: Introduction · Ohmic drop · Corrosion current measurement in presence of an ohmic drop · ZIR Technique · STERN Method (TAFEL Fit) · Stern and Geary method

Related products:EC-Lab®SP-300
Download PDF Source: biologic.net · Updated: March 28, 2024

Products related to this class

SP-200
Bio-LogicPremium

SP-200

Portable, research-grade single-channel potentiostat
  • ±500 mA maximum current, 9 current ranges (10 nA – 1 A)
  • EIS option: 10 µHz – 11 MHz
  • ±100 fA accuracy on the 1 pA range with the ULC option
SP-300
Bio-LogicPremium

SP-300

Fast, accurate, stable and modular — grows with your research
  • 2 slots: second channel, bipotentiostat (RRDE) or internal booster
  • Internal booster boards: ±1 A/±48 V, ±2 A/±30 V, ±4 A/[-3;14] V, ±10 A/[-1;6] V
  • EIS 10 µHz – 11 MHz
VSP-300
Bio-LogicPremium

VSP-300

Small footprint, parallel experiments on up to 6 channels
  • 6 slots: up to 6 independent channels
  • EIS 11 MHz and ULC option per channel
  • 4 booster boards in parallel: up to 40 A
M470
Bio-Logic

M470

Ultra-high-resolution scanning platform — 9 modular techniques
  • 9 techniques: SECM, ac-SECM, ic-SECM, LEIS, SVP (SVET), SDS (SDC), ac-SDS, SKP, OSP
  • Positioning resolution 20 nm, scan range 110 mm
  • Max. scan speed 10 mm/s; piezo positioning for ic-SECM
Electrochemical Cells
Bio-Logic

Electrochemical Cells

From 150 µL to 1 L, from -20 °C to 120 °C
  • Small-volume analytical cells (150 µL – 100 mL)
  • Large-volume cells (80 / 150 mL), RDE compatible
  • Corrosion: standard, Avesta, flat, galvanic, plate and coating cells

Would you like to set up this measurement in your laboratory?

Contact our technical team for the suitable instrument, cell and software configuration.